About water filter systems

Reverse osmosis ultrapure water system how to maintain can improve life expectancy

Views : 5538
Author : Susan
Update time : 2024-09-14 10:49:15

Hello, this is a new vision of water treatment,today Susan will come to answer some questions about water treatment equipment, I hope to be able to help you.
In recent years, people's requirements for water quality is more and more high, in order to meet people's needs, reverse osmosis ultrapure water system is therefore born, and meet the public recognition. In order to protect the performance and stability of reverse osmosis membrane treatment, and the need to do a good job of maintenance, equipment maintenance in order to water quality in order to be more stable, so we have organized the following several maintenance methods, please come to understand.

First, avoid frequent switching equipment
In normal operation is the first need to contact the water source,
for the equipment to check the pipeline is the presence of water leakage occurs, check the normal power supply. After the deactivation, to first turn off the power supply after disconnecting the water source. Reverse osmosis equipment in the process of operation to avoid frequent disconnection of the power box in the water supply. Equipment using automatic control devices, frequent disconnections will affect the normal operation of the equipment, reducing the service life of the equipment.

Second, check the service life of the filter cartridge
reverse osmosis ultrapure water system in the long-term use of the process needs to be regularly checked on the cartridge, according to the provisions of the regular replacement of the cartridge, so as to ensure that the water quality of the equipment. If the continuous use of a few months after the decline in the quality of pure water, able to discharge pure water according to the actual situation, while the equipment will automatically backwash function.

Third, the water supply system needs to be independent
The source water in the reverse osmosis water treatment equipment has an independent water supply system, so that you can protect the stable operation of the water supply system, while also reducing the RO membrane on the whole plant water supply network caused by the enormous pressure. When the RO membrane directly from the source water pipeline, then, should set up a high and low pressure protection device, reduce the network due to excessive pressure caused by the wave.


Fourth, do a good job of routine maintenance
Reverse osmosis ultrapure water system needs to do a good job of routine maintenance in the process of operation, so as to ensure the normal operation of the equipment. For water treatment equipment to be checked regularly, but also for reverse osmosis membrane cleaning and sewage, which can avoid reverse osmosis membrane is blocked.

In addition, the reverse osmosis membrane should be replaced in a timely manner to avoid the aging of the water quality. The above is about reverse osmosis ultrapure water system maintenance of several ways, I hope it can help you.
The above is about the general knowledge of water treatment equipment, I hope you can help, if you still want to know more about water treatment in this regard, welcome to leave a message in the comments section or contact me according to the following business card, I will reply as soon as possible. Thank you for reading and have a nice life!
Related News
Read More >>
Do you know how to reduce the operating costs of RO reverse osmosis water treatment plants? Do you know how to reduce the operating costs of RO reverse osmosis water treatment plants?
Sep .29.2024
The principle of reverse osmosis technology is higher than the osmotic pressure of the solution, based on other substances can not pass through the semi-permeable membrane and these substances and water to leave.The membrane pore size of the reverse osmosis membrane is very small, so it can effectively remove dissolved salts, colloids, microorganisms, organic matter, etc. in water.RO system because there is a high-pressure pump, and need to add a special scale inhibitor, high operating costs.How do we reduce the operating costs of the RO system?
Do you know what common instruments/meters are needed for reverse osmosis systems? Do you know what common instruments/meters are needed for reverse osmosis systems?
Sep .29.2024
In order to make the RO device can be safe and reliable operation, easy to monitor the operation process, should be equipped with the necessary instrumentation and control devices, generally need to install the instrumentation has a temperature meter, flow meter, pressure meter, conductivity meter, oxidation potential meter, chlorine meter, pH meter, specific as follows:
Does your reverse osmosis equipment often wash the membrane, change the membrane? Does your reverse osmosis equipment often wash the membrane, change the membrane?
Sep .27.2024
Users reflecting their own purchase of reverse osmosis equipment frequently wash membrane, reverse osmosis membrane use life is short and other issues. Today Susan organized a compilation of reverse osmosis equipment for reference, welcome to exchange, correction.